PRAG 20KVA Servo Stabilizer (80-260V)
Product specification
- Model: PT-20KVA
- Power: 20KVA
- Input voltage: 80V-260V AC
- Technology: Servo Technology Toroidal Transformer System
- Efficiency: > 90%
- Display: LED/LCD Digital Display
- Frequency: 50Hz/60Hz
- Delay Time: Short Delay (3-5 sec)
- Over-voltage protection: AC246 ± 4V
- High Temperature
- Short Circuit
- Output voltage: 220V ± 10%
- Phase: Single
- Dimension: 56 X 51 X 107
- Weight: 147 kg
-
PRAG 30KVA Servo Stabilizer (80-260V)
Product specifications
- Model: TND-30KVA
- Input voltage: 80V-260V AC
- Power: 30KVA
- Technology: Servo Control Toroidal Transformer System
- Efficiency: > 97%
- Display: LED Digital Display
- Frequency: 50Hz/60Hz
- Delay Time: Short Delay (3-5 sec)
- Over-voltage protection: AC246 ± 4V
- High Temperature
- Short Circuit
- Output voltage: 220V ± 10%
- Phase: Single
- Dimension: 56 X 51 X 107
- Weight: 147 kg
-
PRAG 7.5KVA/48V Inverter 8 X 12V 220AH Battery 16 X 250W Solar Panel Roof-Top off-grid Complete Installation
- The PRAG Inverter is Easy to Install and Easy to Operate. This inverter is also Easy to Solve
- It is also designed to Operate under Harsh Environment
- The Inverter comes with the ability to do a DC Start & Automatic Self-Diagnostic Function
- It is Compatible with Both Linear & Non-Linear Load
- Low DC Voltage Supports Home & Office Appliances on the inverter
- With this PRAG Inverter, you can enjoy Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%
- High Efficiency Inverter Design & “Power Saving Mode” to Conserve Energy
- Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration
- 13 Vdc Inverter Battery Recover Point, Dedicated for Renewable Energy Systems
- 8 pre Set Battery Type Selector plus De-sulphation for Totally Flat Inverter Batteries
- 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger
- 8 ms Typical Transfer Time Between Utility & Inverter Battery, Guarantees Power Continuity
- 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator
- Battery DOD(Depth of Discharge)setting from 50% to 100%
-
Q 200Ah 12v Amaron Quanta Tubular DryCell Batteries
- PPCP Containers with Low permeability to ensure that there is no water loss.
- –Side wall design to maintain structural integrity in high operating temperatures.
- –High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
- –Heavy duty L terminal best suited to carry high rate discharges.
- –Highly reliable one way self resealing safety vent seal.
- –MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
- –FLAPPON Terminal protecting system to prevent short circuits.
- –Ergonomic design for easy handling.
- –Grouping the plates by Cast-On-Strap leads to integral lead crystals
- –Provides superior corrosion resistance to negative strap.
- –Superior high rate discharge with low internal resistance.
₦420,000.00₦470,000.00Q 200Ah 12v Amaron Quanta Tubular DryCell Batteries
₦420,000.00₦470,000.00 -
Roll over image to zoom in 10kVA Vectronic Online UPS (C Series with batteries)
Profile: Tower
Rating: 10kVA
Voltage: 220/230Vac
Frequency: 50Hz -
SERNE 4 by 4 Breaker cover
Models HT4830S80-145 HT4840S80-145 HT4850S80-145 AC mode Rated input voltage 220/230Vac Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2% Frequency 50Hz/ 60Hz (automatic detection) Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz); Overload/short circuit protection Circuit breaker Efficiency >95% Conversion time (bypass andinverter) 10ms (typical) AC backflow protection yes Maximum bypass overload current 40A Inverting mode Output voltage waveform Pure sine wave Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Power factor 1 Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable) Output voltage error ±5% Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz Efficiency >92% Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)> (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>
Load>150% ±10%: Report error and turn off output after 5 seconds;
Peak power 6000VA 8000VA 10000VA Loaded motor capacity 2HP 3HP 4HP Output short circuit protection Circuit breaker Bypass circuit breaker specification 63A Rated battery input voltage 48V (minimum starting voltage 44V) Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) Eco mode Load ≤50W AC charge Battery type Lead acid or lithium battery Maximum charge current 60A Charge current error ± 5Adc Charge voltage range 40 –58Vdc Short circuit protection Circuit breaker Circuit breaker specification (AC IN)63A/(BAT)125A Overcharge protection Alarm and turn off charging in 1 minute. Solar charge Maximum PV open circuit voltage 145Vdc PV operating voltage range 60-145Vdc MPPT voltage range 60-115Vdc Battery voltage range 40-60Vdc Maximum output power 4200W PV charge current range (settable) 0-80A Charge short circuit protection BAT circuit breaker and fuse Wiring protection Reverse polarity protection Authentication specification Specification certification CE(EN62109) EMC certification level EN61000,C2 Operating temperature range -15°C to 55°C Storage temperature range -25°C ~ 60°C RH range 5% to 95% (conformal coating protection) Noise ≤60dB Heat dissipation Forced air cooling, adjustable air speed Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control Dimensions (L*W*D) 482mm*425mm*133mm Weight (kg) 13.3