Mercury UPS
Showing all 11 results
-
Inverters, Mercury, Mercury UPS
Mercury 1.6KVA Home UPS Inverter Pure Sine Wave M1600 24v
SPECIFICATION
Voltage Range 180 VAC – 265VAC ± 5 VAC (UPS Mode)
100 VAC – 280 VAC ± 15 VAC (NOR Mode)
Line Low Detection 180V ± 5V (UPS Mode) / 100V ± 15V (NOR Mode)
Line Low Comeback 190V ± 5V (UPS Mode) / 110V ± 10V (NOR Mode)
Line Low Detection 265V ± 5V (UPS Mode) / 280V ± 15V (NOR Mode)
Line Low Comeback 255V ± 5V (UPS Mode) / 270V ± 10V (NOR Mode)
Frequency Transfer Input Frequency 45-55 Hz
CHARACTERISTICS (AC)
Inverter Full Load Power 1200W
Power Factor 0.8 factor (on resistive load)
On-Line Mode Pure Sine Wave
Battery Mode Pure Sine Wave
On-Line Output voltage Follow the Line Voltage
Battery Mode Output Voltage 200 VAC ± 10%
Transfer Time (No-Load) <15 ms
The frequency at Battery Mode 50 Hz ± 1 Hz
Characteristics (DC)
DC Supply Voltage 24V
Battery Floating Charge Voltage 27.0 VDC ± 0.4 VDC
Charge Current <15 A
Battery Voltage Low Alarm 21.2 VDC ± 0.4 VDC
Battery Discharge Protection 20.8 VDC ± 0.4 VDC
Over Charge Protection > 30 VDC ± 0.4 VDC
Color Box Parameters 20×16.5×10.6 (LxWxH) Inch
Weight 17.2 (Kg)
SKU: n/a -
Mercury UPS, Uninterrupted Power Supply(UPS)
MERCURY 10KVA ONLINE UPS , SINGLE PHASE ONLINE MERCURY UNITERUPTIBLE POWER SUPPLY HP9110C-S
Mercury UPS, Uninterrupted Power Supply(UPS)MERCURY 10KVA ONLINE UPS , SINGLE PHASE ONLINE MERCURY UNITERUPTIBLE POWER SUPPLY HP9110C-S
Specifications
Power 6KVA / 4200W Voltage range 176 ±5VAC~276 ±5VAC Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto sensing Input phase Single phase Power factor ≥0.98 Voltage range 220VAC ±1% Output phase Single pha se Frequency 50Hz ±0.2% (battery mode) THD < 2% (Linear load); < 6% (non-Linear load) Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass modeCrest factor 3:1 (max) Waveform Pure sine wave Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)Efficiency ≥88% AC mode 5 cycles turn off inverter, no transfer to Bypass,
provide alarm.Battery mode 5 cycles turn off inverter, provide alarm. Bypass mode Input fuse blown or break action. Battery Model 12V sealed lead acid maintenance free DC voltage 240VDC Configuration 20x 12V/8.2AH Backup time 20min (half load) / 7min (full load) Charge current 1A (standard unit) / 5A (long time unit) Recharge time 90% capacity after 8hrs charging Communication Interface RS232; SNMP (optional) Parallel Port Parallel availability for redundancy and load sharing up to three unit LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operationNoise level ≤ 55dB Temperature 0~40˚C; 0 ~ 40˚C (storage temperature) Humidity 0~95% (non-condensing) Altitude < 1500m Weight Net/Gross 89/104kg (standard unit); 34/48kg (long time unit) Dimension (WxDxH) 270 x 570 x 720mm Packaging (WxDxH) 370 x 670 x 940mm SKU: n/a -
Mercury, Mercury UPS
Mercury 1kva Home UPS Inverter Pure Sine Wave M1000 12v
SPECIFICATION
Voltage Range 180 VAC – 265VAC ± 5 VAC (UPS Mode)
100 VAC – 280 VAC ± 15 VAC (NOR Mode)
Line Low Detection 180V ± 5V (UPS Mode) / 100V ± 15V (NOR Mode)
Line Low Comeback 190V ± 5V (UPS Mode) / 110V ± 10V (NOR Mode)
Line Low Detection 265V ± 5V (UPS Mode) / 280V ± 15V (NOR Mode)
Line Low Comeback 255V ± 5V (UPS Mode) / 270V ± 10V (NOR Mode)
Frequency Transfer Input Frequency 45-55 Hz
CHARACTERISTICS (AC)
Inverter Full Load Power 460W
Power Factor 0.8 factor (on resistive load)
On-Line Mode Sine Wave
Battery Mode Sine Wave
On-Line Output voltage Follow the Line Voltage
Battery Mode Output Voltage 200 VAC ± 10%
Transfer Time (No-Load) <15 ms
The frequency at Battery Mode 50 Hz ± 1 Hz
Characteristics (DC)
DC Supply Voltage 12V
Battery Floating Charge Voltage 13.5 VDC ± 0.2 VDC
Charge Current <15 A
Battery Voltage Low Alarm 10.6 VDC ± 0.2 VDC
Battery Discharge Protection 10.4 VDC ± 0.2 VDC
Over Charge Protection > 15 VDC ± 0.2VDC
Color Box Parameters 15.5x14x8.8 (LxWxH) Inch
Weight 10.7 (Kg)
SKU: n/a -
Mercury UPS, Uninterrupted Power Supply(UPS)
MERCURY 3KVA ONLINE UPS SINGLE PHASE ONLINE MERCURY UNITERUPTIBLE POWER SUPPLY HP930C-S
Mercury UPS, Uninterrupted Power Supply(UPS)MERCURY 3KVA ONLINE UPS SINGLE PHASE ONLINE MERCURY UNITERUPTIBLE POWER SUPPLY HP930C-S
Specifications
Capacity 3KVA / 2400W Phase Single Phase Input voltage 115VAC(±5) ~ 295VAC(±5) if load ≤ 70%; 160VAC(±5) ~ 295VAC(±5) if load ≥ 70% Frequency 46 ~ 54(50Hz)±0.5Hz; 56 ~ 64(60Hz)±0.5Hz auto-sensing Input power factor ≥ 0.97 Output voltage 220/230VAC ± 2% Frequency 50Hz / 60Hz ± 0.2% THD < 3% (linear load); < 5% (non linear load) Overload capability > 110%, 30s turn to bypass mode; > 150%, 300ms turn to bypass mode Crest factor 3:1 (max) AC Mode: 10 cycles, when voltage lower than rated 30%,
and inrush current higher than rated 70%,
turn off the inverter, no transfer to bypass,
give alarmBattery Mode: 10 cycles, when voltage lower than rated 30%
and inrush current higher than rated 70%,
turn off the inverter, give an alarmBypass Mode: Input fuse blew or break actionWaveform Pure sine wave Transfer time 0ms between AC mode & Bypass mode
4ms (typical 2.5ms) between Inverter mode & Bypass modeEfficiency ≥ 87% Model 12V sealed lead acid maintenance-free Battery 8x 12V / 7AH DC voltage 96VDC Back-up 12min (half load); 5min (full load) Recharge time 8hours ~ 90% capacity Charge current 1A(standard unit);6A(long-time unit) Communication interface RS232 ; SNMP (optional) LED indication Load or battery capacity Noise level < 45dB Temperature 0 ~ 40˚C Humidity 0% ~ 95% (non-condensing) Altitude < 1500m Storage temperature -25 ~ 55˚C Standard unit (net/gross) 28/30.5 kg Long-time unit (net/gross) 11/13 kg Dimension (WxDxH)mm 190 x 468 x 339 Packing(WxDxH)mm 275 x 563 x 446 SKU: n/a -
Mercury UPS, Uninterrupted Power Supply(UPS)
MERCURY 6KVA ONLINE UPS SINGLE PHASE ONLINE MERCURY UNITERUPTIBLE POWER SUPPLY HP960C-S
Mercury UPS, Uninterrupted Power Supply(UPS)MERCURY 6KVA ONLINE UPS SINGLE PHASE ONLINE MERCURY UNITERUPTIBLE POWER SUPPLY HP960C-S
Specifications
Power 6KVA / 4200W Voltage range 176 ±5VAC~276 ±5VAC Frequency 46~54Hz ±0.5Hz, or 56~64Hz ±0.5Hz auto sensing Input phase Single phase Power factor ≥0.98 Voltage range 220VAC ±1% Output phase Single pha se Frequency 50Hz ±0.2% (battery mode) THD < 2% (Linear load); < 6% (non-Linear load) Overload 105%~130% 10min turn to Bypass mode,
> 130% 1s turn to Bypass modeCrest factor 3:1 (max) Waveform Pure sine wave Transfer time 0ms (AC mode – Battery mode)
0ms (AC mode – Bypass mode)Efficiency ≥88% AC mode 5 cycles turn off inverter, no transfer to Bypass,
provide alarm.Battery mode 5 cycles turn off inverter, provide alarm. Bypass mode Input fuse blown or break action. Battery Model 12V sealed lead acid maintenance free DC voltage 240VDC Configuration 20x 12V/8.2AH Backup time 20min (half load) / 7min (full load) Charge current 1A (standard unit) / 5A (long time unit) Recharge time 90% capacity after 8hrs charging Communication Interface RS232; SNMP (optional) Parallel Port Parallel availability for redundancy and load sharing up to three unit LCD Indication Input voltage/frequency; battery voltage; output voltage/frequency; load watt/VA value & percent; inverter temperature; operation mode such as “on batt” or “on bypass” LED Indication Green: normal operation; Yellow: warning condition
Red: abnormal operationNoise level ≤ 55dB Temperature 0~40˚C; 0 ~ 40˚C (storage temperature) Humidity 0~95% (non-condensing) Altitude < 1500m Weight Net/Gross 89/104kg (standard unit); 34/48kg (long time unit) Dimension (WxDxH) 270 x 570 x 720mm Packaging (WxDxH) 370 x 670 x 940mm SKU: n/a