Max 3kW/24V Transformer Based Inverter (60A)
Feature of max solar 3kva Hybrid Inverter:
1.Pure sine wave inverter
2.Built-in MPPT solar charge controller
3.Selectable input voltage range for home appliances and personal computers
4.Selectable charging current based on applications
5.Configurable AC/Solar input priority via LCD setting
6.Compatible to mains voltage or generator power
7.Auto restart while AC is recovering
8.Overload and short circuit protection
9.Smart battery charger design for optimized battery performance
10.Cold start function
11.Optional Remote Control Panel available -
Max 5.5kW/48V Transformerless Inverter (100A)
Feature of max solar 3kva Hybrid Inverter:
1.Pure sine wave inverter
2.Built-in MPPT solar charge controller
3.Selectable input voltage range for home appliances and personal computers
4.Selectable charging current based on applications
5.Configurable AC/Solar input priority via LCD setting
6.Compatible to mains voltage or generator power
7.Auto restart while AC is recovering
8.Overload and short circuit protection
9.Smart battery charger design for optimized battery performance
10.Cold start function
11.Optional Remote Control Panel available -
Max 5kW/48V Transformer Based Inverter (60A)
Feature of max solar 3kva Hybrid Inverter:
1.Pure sine wave inverter
2.Built-in MPPT solar charge controller
3.Selectable input voltage range for home appliances and personal computers
4.Selectable charging current based on applications
5.Configurable AC/Solar input priority via LCD setting
6.Compatible to mains voltage or generator power
7.Auto restart while AC is recovering
8.Overload and short circuit protection
9.Smart battery charger design for optimized battery performance
10.Cold start function
11.Optional Remote Control Panel available₦600,000.00₦700,000.00Max 5kW/48V Transformer Based Inverter (60A)
₦600,000.00₦700,000.00 -
Max 5kW/48V Transformerless Inverter (80A)
Feature of max solar 3kva Hybrid Inverter:
1.Pure sine wave inverter
2.Built-in MPPT solar charge controller
3.Selectable input voltage range for home appliances and personal computers
4.Selectable charging current based on applications
5.Configurable AC/Solar input priority via LCD setting
6.Compatible to mains voltage or generator power
7.Auto restart while AC is recovering
8.Overload and short circuit protection
9.Smart battery charger design for optimized battery performance
10.Cold start function
11.Optional Remote Control Panel available -
MPPT Solar Charging Controller MA2460N15
◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
◆Support CAN communication function (optional).
◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
◆Support starting capacitive load and inductive load.
◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment. -
Q 200Ah 12v Amaron Quanta Tubular DryCell Batteries
- PPCP Containers with Low permeability to ensure that there is no water loss.
- –Side wall design to maintain structural integrity in high operating temperatures.
- –High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
- –Heavy duty L terminal best suited to carry high rate discharges.
- –Highly reliable one way self resealing safety vent seal.
- –MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
- –FLAPPON Terminal protecting system to prevent short circuits.
- –Ergonomic design for easy handling.
- –Grouping the plates by Cast-On-Strap leads to integral lead crystals
- –Provides superior corrosion resistance to negative strap.
- –Superior high rate discharge with low internal resistance.
₦420,000.00₦470,000.00Q 200Ah 12v Amaron Quanta Tubular DryCell Batteries
₦420,000.00₦470,000.00 -
Roll over image to zoom in 10kVA Vectronic Online UPS (C Series with batteries)
Profile: Tower
Rating: 10kVA
Voltage: 220/230Vac
Frequency: 50Hz -
SERNE 4 by 4 Breaker cover
Models HT4830S80-145 HT4840S80-145 HT4850S80-145 AC mode Rated input voltage 220/230Vac Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2% Frequency 50Hz/ 60Hz (automatic detection) Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz); Overload/short circuit protection Circuit breaker Efficiency >95% Conversion time (bypass andinverter) 10ms (typical) AC backflow protection yes Maximum bypass overload current 40A Inverting mode Output voltage waveform Pure sine wave Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Power factor 1 Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable) Output voltage error ±5% Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz Efficiency >92% Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)> (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>
Load>150% ±10%: Report error and turn off output after 5 seconds;
Peak power 6000VA 8000VA 10000VA Loaded motor capacity 2HP 3HP 4HP Output short circuit protection Circuit breaker Bypass circuit breaker specification 63A Rated battery input voltage 48V (minimum starting voltage 44V) Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) Eco mode Load ≤50W AC charge Battery type Lead acid or lithium battery Maximum charge current 60A Charge current error ± 5Adc Charge voltage range 40 –58Vdc Short circuit protection Circuit breaker Circuit breaker specification (AC IN)63A/(BAT)125A Overcharge protection Alarm and turn off charging in 1 minute. Solar charge Maximum PV open circuit voltage 145Vdc PV operating voltage range 60-145Vdc MPPT voltage range 60-115Vdc Battery voltage range 40-60Vdc Maximum output power 4200W PV charge current range (settable) 0-80A Charge short circuit protection BAT circuit breaker and fuse Wiring protection Reverse polarity protection Authentication specification Specification certification CE(EN62109) EMC certification level EN61000,C2 Operating temperature range -15°C to 55°C Storage temperature range -25°C ~ 60°C RH range 5% to 95% (conformal coating protection) Noise ≤60dB Heat dissipation Forced air cooling, adjustable air speed Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control Dimensions (L*W*D) 482mm*425mm*133mm Weight (kg) 13.3