• APC Smart-UPS 3000VA 230V

    Key Features
    • Output power capacity…………………….2.7kilowatts/3KVA
    • Nominal Output Voltage…………………..230V
    • Output voltage distortion………………….less than 5% at full load
    • Topology………………………………………..Line Interative
    • Waveform type……………………………….Sine wave
    • Typical reccharge tim………………………3 hours
    • Exected battery life…………………………3-5 years
    • Interface ports……………………………….Smartslots,USB
    • Surge Energy rating……………………….365 joules
    • warranty………………………………………..two years warranty from date of purchase.
  • APC Smart-UPS 750VA LCD 230V – SMT750I

    • Output Power Capacity: 500 Watts / 750 VA
    • Max Configurable Power: 500 Watts / 750 VA
    • Nominal Output Voltage: 230V
    • Output Voltage Distortion: Less than 5% at full load
    • Topology: Line Interactive
    • Waveform Type: Sine wave
    • Other Input Voltages: 220, 240
  • APC Smart-UPS SRT 6000VA 230V – SRT6KXLI

    Specification:

    • Output Power Capacity: 2700 Watts / 3000 VA
    • Max Configurable Power: 2700 Watts / 3000 VA
    • Nominal Output Voltage: 230V
    • Output Voltage Note: Configurable for 220 : 230 or 240 nominal output voltage
    • Efficiency at Full Load: 95.0%
    • Output Voltage Distortion: Less than 5% at full load
    • Output Frequency (sync to mains): 47 – 53 Hz for 50 Hz nominal, 57 – 63 Hz for 60 Hz nominal
    • Topology: Line Interactive
    • Waveform Type: Sine wave
    • Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
    • Typical recharge time: 3 hour(s)
    • Replacement Battery: RBC55
  • GROWATT INVERTER 7.5KVA/48V

    * BATTERY TYPES  – LEAD ACID AND LITHIUM(LiFePo4)
    * CONFIGURABLE SOLAR OR GRID INPUT PRIORITY
    * OFF GRID SOLAR INVERTER
    * PURE COPPER TRANSFORMER
    * 240V SINGLE PHASE OUTPUT
    * INTEGRATED MPPT CHARGE CONTROLLER
    * SUPER SILENT OPERATION
    * 150V – 285V A/C INPUT THRESHOLD OPERATING RANGE.
    * UP TO 75AMPS/SECOND BATTERY CHARGING CAPABILITY
    * 5 STAGE ADVANCED ADJUSTABLE AC CHARGING CURRENT
    * ABILITY TO SHUT OFF AC CHARGING
    * AC/DC PRIORITY MODES CAN BE SET
    * GENERATOR AUTOMATIC SIGNAL(DRY CONTACT)
    * AUTO SELF TEST ON LCD SUPER DIGITAL DISPLAY
    * EFFICIENCY OF 99+%
    * GALVANIC ISOLATION
    * INTEGRATED AUTOMATIC VOLTAGE REGULATOR
    * PURE SINE WAVE INVERTER
    * AUTOMATIC A/C MAINS BYPASS
    * PURE AUTOMATIC INTEGRATION TO UTILITY MAINS ELECTRICITY
    * NEW CUTTING EDGE TECHNOLOGY IN INVERTER ENGINEERING
    * LOW BATTERY, OVERLOAD, OVER TEMPERATURE, SHORT CIRCUIT PROTECTION
    * OVERLOAD, ABNORMAL AC INPUT, LOW BATTERY UPS FAILURE ALARM
    * BATTERY SELECTION TO CHARGE ALL BATTERY TYPES
    * GREAT FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATION
    * POWER FACTOR 0.98
    * INTEGRATED 60A MPPT SOLAR CHARGE CONTROLLER
    * MAN-MACHINE INTELLIGENT DESIGN (AI)
  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • RiiO 2KVA/48V -M Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3