• APC Smart-UPS SRT 6000VA 230V – SRT6KXLI

    Specification:

    • Output Power Capacity: 2700 Watts / 3000 VA
    • Max Configurable Power: 2700 Watts / 3000 VA
    • Nominal Output Voltage: 230V
    • Output Voltage Note: Configurable for 220 : 230 or 240 nominal output voltage
    • Efficiency at Full Load: 95.0%
    • Output Voltage Distortion: Less than 5% at full load
    • Output Frequency (sync to mains): 47 – 53 Hz for 50 Hz nominal, 57 – 63 Hz for 60 Hz nominal
    • Topology: Line Interactive
    • Waveform Type: Sine wave
    • Battery Type: Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
    • Typical recharge time: 3 hour(s)
    • Replacement Battery: RBC55
  • Max 3.2kW/24V Transformerless Inverter (80A)

    Feature of max solar 3kva Hybrid Inverter:

    1.Pure sine wave inverter
    2.Built-in MPPT solar charge controller
    3.Selectable input voltage range for home appliances and personal computers
    4.Selectable charging current based on applications
    5.Configurable AC/Solar input priority via LCD setting
    6.Compatible to mains voltage or generator power
    7.Auto restart while AC is recovering
    8.Overload and short circuit protection
    9.Smart battery charger design for optimized battery performance
    10.Cold start function
    11.Optional Remote Control Panel available

  • Max 3kW/24V Transformer Based Inverter (60A)

    Feature of max solar 3kva Hybrid Inverter:

    1.Pure sine wave inverter
    2.Built-in MPPT solar charge controller
    3.Selectable input voltage range for home appliances and personal computers
    4.Selectable charging current based on applications
    5.Configurable AC/Solar input priority via LCD setting
    6.Compatible to mains voltage or generator power
    7.Auto restart while AC is recovering
    8.Overload and short circuit protection
    9.Smart battery charger design for optimized battery performance
    10.Cold start function
    11.Optional Remote Control Panel available

  • Max 5.5kW/48V Transformerless Inverter (100A)

    Feature of max solar 3kva Hybrid Inverter:

    1.Pure sine wave inverter
    2.Built-in MPPT solar charge controller
    3.Selectable input voltage range for home appliances and personal computers
    4.Selectable charging current based on applications
    5.Configurable AC/Solar input priority via LCD setting
    6.Compatible to mains voltage or generator power
    7.Auto restart while AC is recovering
    8.Overload and short circuit protection
    9.Smart battery charger design for optimized battery performance
    10.Cold start function
    11.Optional Remote Control Panel available

  • Max 5kW/48V Transformer Based Inverter (60A)

    Feature of max solar 3kva Hybrid Inverter:

    1.Pure sine wave inverter
    2.Built-in MPPT solar charge controller
    3.Selectable input voltage range for home appliances and personal computers
    4.Selectable charging current based on applications
    5.Configurable AC/Solar input priority via LCD setting
    6.Compatible to mains voltage or generator power
    7.Auto restart while AC is recovering
    8.Overload and short circuit protection
    9.Smart battery charger design for optimized battery performance
    10.Cold start function
    11.Optional Remote Control Panel available

    600,000.00700,000.00
  • Max 5kW/48V Transformerless Inverter (80A)

    Feature of max solar 3kva Hybrid Inverter:

    1.Pure sine wave inverter
    2.Built-in MPPT solar charge controller
    3.Selectable input voltage range for home appliances and personal computers
    4.Selectable charging current based on applications
    5.Configurable AC/Solar input priority via LCD setting
    6.Compatible to mains voltage or generator power
    7.Auto restart while AC is recovering
    8.Overload and short circuit protection
    9.Smart battery charger design for optimized battery performance
    10.Cold start function
    11.Optional Remote Control Panel available

  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3