• 30kVA Zektron Online UPS 3-Phase ZT33 series

    Zektron 3phase online ups ZT-33 series is a 7 inch Touch Screen LCD, high frequency, double conversion online UPS. It applies advanced technology that increases performance and reliability: Its two high speed dsps with completed digital control fully ensure high quality of power supply. Ideal for computers, data center, medical apparatus, telecom equipments, etc.

  • 3kVA 24v Inverter ISH series

    Zektron ISH series is a pure sine wave inverter with fully digital microprocessor control and a wider input voltage, this inverter is compatible with generators. With its transformer design, it can provide more protection to the load which is under unstable power condition

  • 40A MPPT SOLAR CHARGE CONTROLLER

    The Rilso Power MPK Series of solar charge controllers adopts the latest innovation of MPPT solar charge controllers. This series of solar charge controllers utilize both fan cooling and heat sink cooling system. Hence, it is rugged and performs well in various environments.

    When in need of a high-performance and effective maximum power point tracking solar charge controller (MPPT), Rilso Power MPK series is one solar charge controller to consider.

    The MPK series of solar charge controllers can continuously track solar panels’ maximum amount of power to charge the battery. MPK series can work with lead acid and lithium batteries. MPK series is available in 40A, 60A, 80A, and 100A.

    18~150vdc 35~150vdc 60~150vdc max. pv input power 12v 520w 24v 1040w 48v 2080w

  • 60kVA Delta transformer-based Online UPS

    Delta 300 DLT series UPS, PWM controlled, IGBT technology, microcontroller controlled, sinusoidal waveform, ONLINE Double Conversion topology and parallel configurable devices. Advanced communication system supports many communication protocols and brings remote control advantage of the UPS.

  • 80A MPPT SOLAR CHARGE CONTROLLER (RILSO POWER)

    In stock

    The Rilso Power MPK Series of solar charge controllers adopts the latest innovation of MPPT solar charge controllers. This series of solar charge controllers utilize both fan cooling and heat sink cooling system. Hence, it is rugged and performs well in various environments.

    When in need of a high-performance and effective maximum power point tracking solar charge controller (MPPT), Rilso Power MPK series is one solar charge controller to consider.

    The MPK series of solar charge controllers can continuously track solar panels’ maximum amount of power to charge the battery. MPK series can work with lead acid and lithium batteries. MPK series is available in 40A, 60A, 80A, and 100A.

  • 80A MPPT Solar Charger controller SCH-80A

    Features

    Intelligent battery management function, extend battery life

    Wide PV input voltage range, convenient for system configuration.

    Multiple working modes to adapt different working occasion.

    Advanced PWM tracking, 99% tracking efficiency

  • Delta 40kVA Transformer-based Online 3Phase UPS

    Delta 300 DLT series UPS, PWM controlled, IGBT technology, microcontroller controlled, sinusoidal waveform, ONLINE Double Conversion topology and parallel configurable devices. Advanced communication system supports many communication protocols and brings remote control advantage of the UPS.

  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • RiiO 2KVA/48V -M Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3