-
3kVA 24v Inverter ISH series
Zektron ISH series is a pure sine wave inverter with fully digital microprocessor control and a wider input voltage, this inverter is compatible with generators. With its transformer design, it can provide more protection to the load which is under unstable power condition
-
40A MPPT SOLAR CHARGE CONTROLLER
The Rilso Power MPK Series of solar charge controllers adopts the latest innovation of MPPT solar charge controllers. This series of solar charge controllers utilize both fan cooling and heat sink cooling system. Hence, it is rugged and performs well in various environments.
When in need of a high-performance and effective maximum power point tracking solar charge controller (MPPT), Rilso Power MPK series is one solar charge controller to consider.
The MPK series of solar charge controllers can continuously track solar panels’ maximum amount of power to charge the battery. MPK series can work with lead acid and lithium batteries. MPK series is available in 40A, 60A, 80A, and 100A.
18~150vdc 35~150vdc 60~150vdc max. pv input power 12v 520w 24v 1040w 48v 2080w
-
60kVA Delta transformer-based Online UPS
Delta 300 DLT series UPS, PWM controlled, IGBT technology, microcontroller controlled, sinusoidal waveform, ONLINE Double Conversion topology and parallel configurable devices. Advanced communication system supports many communication protocols and brings remote control advantage of the UPS.
-
Delta 40kVA Transformer-based Online 3Phase UPS
Delta 300 DLT series UPS, PWM controlled, IGBT technology, microcontroller controlled, sinusoidal waveform, ONLINE Double Conversion topology and parallel configurable devices. Advanced communication system supports many communication protocols and brings remote control advantage of the UPS.
-
₦800,000.00
₦1,000,000.00MERCURY 15KVA 3-PHASE FULLY AUTOMATIC AC VOLTAGE STABILIZER – SERVO AVR 3-PHASE IN / 3-PHASE OUT
₦800,000.00₦1,000,000.00 -
MPPT Solar Charging Controller MA2460N15
◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
◆Support CAN communication function (optional).
◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
◆Support starting capacitive load and inductive load.
◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment. -
SERNE 4 by 4 Breaker cover
Models HT4830S80-145 HT4840S80-145 HT4850S80-145 AC mode Rated input voltage 220/230Vac Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2% Frequency 50Hz/ 60Hz (automatic detection) Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz); Overload/short circuit protection Circuit breaker Efficiency >95% Conversion time (bypass andinverter) 10ms (typical) AC backflow protection yes Maximum bypass overload current 40A Inverting mode Output voltage waveform Pure sine wave Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Power factor 1 Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable) Output voltage error ±5% Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz Efficiency >92% Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)> (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>
Load>150% ±10%: Report error and turn off output after 5 seconds;
Peak power 6000VA 8000VA 10000VA Loaded motor capacity 2HP 3HP 4HP Output short circuit protection Circuit breaker Bypass circuit breaker specification 63A Rated battery input voltage 48V (minimum starting voltage 44V) Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) Eco mode Load ≤50W AC charge Battery type Lead acid or lithium battery Maximum charge current 60A Charge current error ± 5Adc Charge voltage range 40 –58Vdc Short circuit protection Circuit breaker Circuit breaker specification (AC IN)63A/(BAT)125A Overcharge protection Alarm and turn off charging in 1 minute. Solar charge Maximum PV open circuit voltage 145Vdc PV operating voltage range 60-145Vdc MPPT voltage range 60-115Vdc Battery voltage range 40-60Vdc Maximum output power 4200W PV charge current range (settable) 0-80A Charge short circuit protection BAT circuit breaker and fuse Wiring protection Reverse polarity protection Authentication specification Specification certification CE(EN62109) EMC certification level EN61000,C2 Operating temperature range -15°C to 55°C Storage temperature range -25°C ~ 60°C RH range 5% to 95% (conformal coating protection) Noise ≤60dB Heat dissipation Forced air cooling, adjustable air speed Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control Dimensions (L*W*D) 482mm*425mm*133mm Weight (kg) 13.3