• 10Kva Inverter With 8X200 AH Battery

    Capacity 200Ah
    Brand  Genus
    Battery Type Tall Tubular Battery
    Warranty 1 year
    Technology VRLA Battery
    Minimum Order Quantity 1 Pack
  • 1kva Intelligent Inverter

    Stylishly built portable and easy to mount inverter with intelligence charger.Low consumption on battery  leading to long standby time thereby prolonging the lifespan of the battery

  • ABB PowerValue 11 RT 3kVA B 1 Phase Rack Mount UPS

    Feature Highlights

    • True online double conversion (VFI) UPS – single phase input / single phase output.
    • Rack-tower convertible (90-degree rotating display).
    • Best in class double conversion efficiency up to 98% to minimise energy loss.
    • Optimised for modern IT loads with rated output power factor up to 1.0 (unity).
    • Thinnest single phase UPS on the market at only 2 RU (rack units).
    • Flexible configurations for scalable runtime by including external battery modules (EBM).
    • Adjustable DC voltage and battery charger current.
    • Optional external maintenance bypass with PDU (power distribution unit)
  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • POWERHUB 20KVA Voltage Stabiliizer

    This Stabilizer is designed to regularize incoming NEPA/Generator voltage for all electrical and electronic appliances at homes, offices, medical & laboratory, ICT, and data centers.
    SVS Stabilizer is a one size fit all device to address all electrical-related problems and it has these unique features as a comparative advantage over others, wide input voltage(80V-270V), ruggedness, and stability.
    The SVS Technology is based on Servo Motor Control System plus Micro compute programmed control to prevent over or under voltage against home or office appliances connected with the Stabilizer.
    Our 30 kVA voltage stabilizer static and servo-controlled solutions help your loads to have TV / Radio transmitter stations, GSM base stations, image and sound production studios, air – conditioners medical devices, hospitals, neon and laser illuminations, press and textile machines, photograph press machines, submerging pumps, ships, electric motors and all electrical devices sensitive to voltage changes.

  • RiiO 2KVA/48V -M Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3