-
12V 200AH KStar Battery
-
- 1. ROBUST TUBULAR WITH HIGH PRESSURE DIE CASTED SPINE- RESULTING LOW RATE OF SPINE CORROSION.
-
- 2. CERAMIC VENT PLUGS- SPECIAL CERAMIC VENT PLUGS FOR CONTROLLED ACID FUMES.
-
- 3. UNIQUE NEGATIVE PASTE RECIPE FOR HIGH CHARGE ACCEPTANCE
-
- 4. CONSISTENT BACKUP THROUGHOUT LIFE
-
- 5. EXCELLENT BEHAVIOR IN PSOC CONDITION
-
- 6. LOW SELF DISCHARGE
-
- 7. EXCELLENT PERFORMANCE ON DEEP CYCLIC APPLICATION
-
- 8. HIGH DESIGN & SERVICE LIFE
-
- 9. LOW CHANCE OF ACID STRATIFICATION
-
- 10. AVAILABLE IN FACTORY CHARGED CONDITION FOR READY TO USE
-
-
200ah/12v Amaron Quanta HUPS Batteries
PPCP Containers with Low permeability ensure that there is no water loss.
Sidewall design to maintain structural integrity in high operating temperatures.
High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
Heavy-duty L terminal best suited to carry high rate discharges.
Highly reliable one-way self resealing safety vent seal.
MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
FLAPPON Terminal protecting system to prevent short circuits.
Ergonomic design for easy handling.
Grouping the plates by Cast-On-Strap leads to integral lead crystals providing superior corrosion resistance to the negative straps.
Superior high rate discharge with low internal resistance.
Unique heavy-duty, corrosion-resistant alloy for positive grids, to increase cyclic life in a tropical environment
Lower internal resistance for superior high-discharge performance
Instacharge, a patented paste recipe for excellent charge acceptance
Aesthetically designed with a rugged Flappon terminal protector that prevents shorts
Compact, lightweight, factory-charged, explosion-resistant, and environment friendly -
3.3Kva 48v Inverter 145v
1. It adopts full-digital double closed loop control, combined with advanced SPWM technology to output pure sine wave.2. Two output modes: mains electricity bypass and inverter output; uninterrupted power supply.3. Four charging modes: PV Only, Mains Electricity Priority, PV Priority and PV&Mains Electricity hybrid charging.4. Advanced MPPT technology with 99.9% efficiency.5. User-defined charging parameters setting(voltage, current and mode), and suitable for various types of energy storage batteries.6. Rocker switch for AC output control.7. Power saving mode, reduce no-load loss.8. Intelligent variable-speed fan to efficiently dissipate heat and extend system lifespan.9. Lithium battery activation function, allow lead-acid battery and lithium battery access.10. All-round protection for solar panels includes overload and short circuit protection, under-voltage and over-voltage protection and reverse polarity protection.11. Support variety of user-friendly communication modules, such as RS485(GPRS, WiFi, Bluetooth), CAN and USB etc., and feasible to connect with computer and mobile phone to realize remote control.12. Available for 6 units parallel operation. -
Amaron Quanta Battery 12V/200AH
Product Details:
Brand Amaron Quanta Capacity 26Ah to 200Ah Battery Type Sealed Maintenance Free (SMF) Warranty 2 years Voltage 12 V Technology VRLA Battery Condition New Supported UPS Any UPS providing supported charging current Water Indication Level Since it is a Sealed Maintainance Free battery so no water indication level is required. Leak Proof Yes Led Indicator No Country of Origin Made in India Capacity (Ah) 26 Ah to 200 Ah Nominal Voltage 12 V -
MPPT Solar Charging Controller MA2460N15
◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
◆Support CAN communication function (optional).
◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
◆Support starting capacitive load and inductive load.
◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment. -
SERNE 4 by 4 Breaker cover
Models HT4830S80-145 HT4840S80-145 HT4850S80-145 AC mode Rated input voltage 220/230Vac Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2% Frequency 50Hz/ 60Hz (automatic detection) Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz); Overload/short circuit protection Circuit breaker Efficiency >95% Conversion time (bypass andinverter) 10ms (typical) AC backflow protection yes Maximum bypass overload current 40A Inverting mode Output voltage waveform Pure sine wave Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000) Power factor 1 Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable) Output voltage error ±5% Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz Efficiency >92% Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)> (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>
Load>150% ±10%: Report error and turn off output after 5 seconds;
Peak power 6000VA 8000VA 10000VA Loaded motor capacity 2HP 3HP 4HP Output short circuit protection Circuit breaker Bypass circuit breaker specification 63A Rated battery input voltage 48V (minimum starting voltage 44V) Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set) Eco mode Load ≤50W AC charge Battery type Lead acid or lithium battery Maximum charge current 60A Charge current error ± 5Adc Charge voltage range 40 –58Vdc Short circuit protection Circuit breaker Circuit breaker specification (AC IN)63A/(BAT)125A Overcharge protection Alarm and turn off charging in 1 minute. Solar charge Maximum PV open circuit voltage 145Vdc PV operating voltage range 60-145Vdc MPPT voltage range 60-115Vdc Battery voltage range 40-60Vdc Maximum output power 4200W PV charge current range (settable) 0-80A Charge short circuit protection BAT circuit breaker and fuse Wiring protection Reverse polarity protection Authentication specification Specification certification CE(EN62109) EMC certification level EN61000,C2 Operating temperature range -15°C to 55°C Storage temperature range -25°C ~ 60°C RH range 5% to 95% (conformal coating protection) Noise ≤60dB Heat dissipation Forced air cooling, adjustable air speed Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control Dimensions (L*W*D) 482mm*425mm*133mm Weight (kg) 13.3