• 200ah/12v Amaron Quanta HUPS Batteries

    PPCP Containers with Low permeability ensure that there is no water loss.
    Sidewall design to maintain structural integrity in high operating temperatures.
    High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
    Heavy-duty L terminal best suited to carry high rate discharges.
    Highly reliable one-way self resealing safety vent seal.
    MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
    FLAPPON Terminal protecting system to prevent short circuits.
    Ergonomic design for easy handling.
    Grouping the plates by Cast-On-Strap leads to integral lead crystals providing superior corrosion resistance to the negative straps.
    Superior high rate discharge with low internal resistance.
    Unique heavy-duty, corrosion-resistant alloy for positive grids, to increase cyclic life in a tropical environment
    Lower internal resistance for superior high-discharge performance
    Instacharge, a patented paste recipe for excellent charge acceptance
    Aesthetically designed with a rugged Flappon terminal protector that prevents shorts
    Compact, lightweight, factory-charged, explosion-resistant, and environment friendly

  • ABB PowerValue 11 RT 3kVA B 1 Phase Rack Mount UPS

    Feature Highlights

    • True online double conversion (VFI) UPS – single phase input / single phase output.
    • Rack-tower convertible (90-degree rotating display).
    • Best in class double conversion efficiency up to 98% to minimise energy loss.
    • Optimised for modern IT loads with rated output power factor up to 1.0 (unity).
    • Thinnest single phase UPS on the market at only 2 RU (rack units).
    • Flexible configurations for scalable runtime by including external battery modules (EBM).
    • Adjustable DC voltage and battery charger current.
    • Optional external maintenance bypass with PDU (power distribution unit)
  • Amaron Quanta Battery 12V/200AH

    Product Details:

    Brand Amaron Quanta
    Capacity 26Ah to 200Ah
    Battery Type Sealed Maintenance Free (SMF)
    Warranty 2 years
    Voltage 12 V
    Technology VRLA
    Battery Condition New
    Supported UPS Any UPS providing supported charging current
    Water Indication Level Since it is a Sealed Maintainance Free battery so no water indication level is required.
    Leak Proof Yes
    Led Indicator No
    Country of Origin Made in India
    Capacity (Ah) 26 Ah to 200 Ah
    Nominal Voltage 12 V
    330,000.00400,000.00

    Amaron Quanta Battery 12V/200AH

    330,000.00400,000.00
  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3
  • SRNE 100A 48v 250v Solar Charge Controller

    1. With the PowerCatcher MPPT technology, the controller is able to track the maximum power point of solar panels even in a complex environment. It has higher response speed and tracking efficiency compared with those controllers with traditional MPPT technology.
    2. The maximum power point tracking algorithm can significantly improve the energy utilization efficiency of photovoltaic systems. The charging efficiency is 15% to 20% higher than the conventional PWM method.
    3. MPPT Tracking efficiency is up to 99.9%.
    4. Advanced digital power technology raises the circuit energy conversion efficiency to 98%.
    5. The controller features a limited current charging mode. When the solar panel power exceeds a certain level and charging current is larger than the rated current, the controller will automatically lower the charging power and bring the charging current to the rated level.
    6. Support charging lithium batteries, gel batteries, sealed batteries and vented batteries, etc.
    7. The controller has an overheat protection mechanism. With charging line loss compensation, the voltage of the battery terminal can be accurately controlled.
    8. The controller features a limited current charging mode. When the solar panel power exceeds a certain level and charging current is larger than the rated current, the controller will automatically lower the charging power and bring the charging current to the rated level.
    9. The controller has an overheat protection mechanism. When the temperature exceeds the set value, the charging current will decline in linear proportion and discharging will be shut off so as to curb the temperature rise of the controller and keep the controller from being damaged by overheat.
    10. It supports parallel operation and meets need of greater charging power.
    11. With embedded bluetooth 4.0BLE module, it can achieve data interaction with APP on mobile phone.
    12. Supports standard Modbus protocol and provides protocol technology support to facilitate secondary development and application by users.
    13. Programmable relay output.

Main Menu