• 12V 200AH KStar Battery

      1. 1. ROBUST TUBULAR WITH HIGH PRESSURE DIE CASTED SPINE- RESULTING LOW RATE OF SPINE CORROSION.
      1. 2. CERAMIC VENT PLUGS- SPECIAL CERAMIC VENT PLUGS FOR CONTROLLED ACID FUMES.
      1. 3. UNIQUE NEGATIVE PASTE RECIPE FOR HIGH CHARGE ACCEPTANCE
      1. 4. CONSISTENT BACKUP THROUGHOUT LIFE
      1. 5. EXCELLENT BEHAVIOR IN PSOC CONDITION
      1. 6. LOW SELF DISCHARGE
      1. 7. EXCELLENT PERFORMANCE ON DEEP CYCLIC APPLICATION
      1. 8. HIGH DESIGN & SERVICE LIFE
      1. 9. LOW CHANCE OF ACID STRATIFICATION
      1. 10. AVAILABLE IN FACTORY CHARGED CONDITION FOR READY TO USE

     

  • 16” Solar Rechargeable Fan

    Brand Name: Lontor
    Product Type: Standing Fan
    Voltage: AC110-230V/50-60Hz
    Battery: 12V 4.8Ah rechargeable battery
    LED Lights: 12 LEDs
    Fan: 3 Speeds Setting
    Duration: 30hours for LED strong light
    – 120hours for LED dim light
    – 5hours for fan in “HIGH” speed function
    – 8hours for fan in “MEDIUM” speed function
    13hours for fan in “LOW” speed function
    Timer: 0.5hour (the working fan will be off automatically after half an hour.)
    Size of the fan: 16 inches

    SOLAR panel : 20 watts 18 volts ( faster charging compared to 15W and 10W)

    70,000.00100,000.00

    16” Solar Rechargeable Fan

    70,000.00100,000.00
  • 3.3Kva 48v Inverter 145v

    1. It adopts full-digital double closed loop control, combined with advanced SPWM technology to output pure sine wave.
    2. Two output modes: mains electricity bypass and inverter output; uninterrupted power supply.
    3. Four charging modes: PV Only, Mains Electricity Priority, PV Priority and PV&Mains Electricity hybrid charging.
    4. Advanced MPPT technology with 99.9% efficiency.
    5. User-defined charging parameters setting(voltage, current and mode), and suitable for various types of energy storage batteries.
    6. Rocker switch for AC output control.
    7. Power saving mode, reduce no-load loss.
    8. Intelligent variable-speed fan to efficiently dissipate heat and extend system lifespan.
    9. Lithium battery activation function, allow lead-acid battery and lithium battery access.
    10. All-round protection for solar panels includes overload and short circuit protection, under-voltage and over-voltage protection and reverse polarity protection.
    11. Support variety of user-friendly communication modules, such as RS485(GPRS, WiFi, Bluetooth), CAN and USB etc., and feasible to connect with computer and mobile phone to realize remote control.
    12. Available for 6 units parallel operation.
  • M-POWER INVERTER 3.5KVA/24V

    • Extremely compact, efficient & reliable
    • Easy to install and use
    • Built in display provides battery and inverter status
    • Huge surge power ability for starting difficult loads
    • Optional remote On/Off panel
  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3