• 12V 200AH KStar Battery

      1. 1. ROBUST TUBULAR WITH HIGH PRESSURE DIE CASTED SPINE- RESULTING LOW RATE OF SPINE CORROSION.
      1. 2. CERAMIC VENT PLUGS- SPECIAL CERAMIC VENT PLUGS FOR CONTROLLED ACID FUMES.
      1. 3. UNIQUE NEGATIVE PASTE RECIPE FOR HIGH CHARGE ACCEPTANCE
      1. 4. CONSISTENT BACKUP THROUGHOUT LIFE
      1. 5. EXCELLENT BEHAVIOR IN PSOC CONDITION
      1. 6. LOW SELF DISCHARGE
      1. 7. EXCELLENT PERFORMANCE ON DEEP CYCLIC APPLICATION
      1. 8. HIGH DESIGN & SERVICE LIFE
      1. 9. LOW CHANCE OF ACID STRATIFICATION
      1. 10. AVAILABLE IN FACTORY CHARGED CONDITION FOR READY TO USE

     

  • 200ah/12v Amaron Quanta HUPS Batteries

    PPCP Containers with Low permeability ensure that there is no water loss.
    Sidewall design to maintain structural integrity in high operating temperatures.
    High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
    Heavy-duty L terminal best suited to carry high rate discharges.
    Highly reliable one-way self resealing safety vent seal.
    MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
    FLAPPON Terminal protecting system to prevent short circuits.
    Ergonomic design for easy handling.
    Grouping the plates by Cast-On-Strap leads to integral lead crystals providing superior corrosion resistance to the negative straps.
    Superior high rate discharge with low internal resistance.
    Unique heavy-duty, corrosion-resistant alloy for positive grids, to increase cyclic life in a tropical environment
    Lower internal resistance for superior high-discharge performance
    Instacharge, a patented paste recipe for excellent charge acceptance
    Aesthetically designed with a rugged Flappon terminal protector that prevents shorts
    Compact, lightweight, factory-charged, explosion-resistant, and environment friendly

  • 3.3Kva 48v Inverter 145v

    1. It adopts full-digital double closed loop control, combined with advanced SPWM technology to output pure sine wave.
    2. Two output modes: mains electricity bypass and inverter output; uninterrupted power supply.
    3. Four charging modes: PV Only, Mains Electricity Priority, PV Priority and PV&Mains Electricity hybrid charging.
    4. Advanced MPPT technology with 99.9% efficiency.
    5. User-defined charging parameters setting(voltage, current and mode), and suitable for various types of energy storage batteries.
    6. Rocker switch for AC output control.
    7. Power saving mode, reduce no-load loss.
    8. Intelligent variable-speed fan to efficiently dissipate heat and extend system lifespan.
    9. Lithium battery activation function, allow lead-acid battery and lithium battery access.
    10. All-round protection for solar panels includes overload and short circuit protection, under-voltage and over-voltage protection and reverse polarity protection.
    11. Support variety of user-friendly communication modules, such as RS485(GPRS, WiFi, Bluetooth), CAN and USB etc., and feasible to connect with computer and mobile phone to realize remote control.
    12. Available for 6 units parallel operation.
  • Amaron Quanta Battery 12V/200AH

    Product Details:

    Brand Amaron Quanta
    Capacity 26Ah to 200Ah
    Battery Type Sealed Maintenance Free (SMF)
    Warranty 2 years
    Voltage 12 V
    Technology VRLA
    Battery Condition New
    Supported UPS Any UPS providing supported charging current
    Water Indication Level Since it is a Sealed Maintainance Free battery so no water indication level is required.
    Leak Proof Yes
    Led Indicator No
    Country of Origin Made in India
    Capacity (Ah) 26 Ah to 200 Ah
    Nominal Voltage 12 V
    330,000.00400,000.00

    Amaron Quanta Battery 12V/200AH

    330,000.00400,000.00
  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • Q 200Ah 12v Amaron Quanta Tubular DryCell Batteries

    • PPCP Containers with Low permeability to ensure that there is no water loss.
    • –Side wall design to maintain structural integrity in high operating temperatures.
    • –High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
    • –Heavy duty L terminal best suited to carry high rate discharges.
    • –Highly reliable one way self resealing safety vent seal.
    • –MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
    • –FLAPPON Terminal protecting system to prevent short circuits.
    • –Ergonomic design for easy handling.
    • –Grouping the plates by Cast-On-Strap leads to integral lead crystals
    • –Provides superior corrosion resistance to negative strap.
    • –Superior high rate discharge with low internal resistance.
    420,000.00470,000.00
  • RiiO 2KVA/48V -M Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3

Main Menu