• Q 200Ah 12v Amaron Quanta Tubular DryCell Batteries

    • PPCP Containers with Low permeability to ensure that there is no water loss.
    • –Side wall design to maintain structural integrity in high operating temperatures.
    • –High Compression Absorbent Glass Mat (AGM) Separator for greater than 98% recombination efficiency.
    • –Heavy duty L terminal best suited to carry high rate discharges.
    • –Highly reliable one way self resealing safety vent seal.
    • –MFX alloy grid for high design life in float @ 27° C with maximum cyclic life.
    • –FLAPPON Terminal protecting system to prevent short circuits.
    • –Ergonomic design for easy handling.
    • –Grouping the plates by Cast-On-Strap leads to integral lead crystals
    • –Provides superior corrosion resistance to negative strap.
    • –Superior high rate discharge with low internal resistance.
    420,000.00470,000.00
  • Amaron Quanta Battery 12V/200AH

    Product Details:

    Brand Amaron Quanta
    Capacity 26Ah to 200Ah
    Battery Type Sealed Maintenance Free (SMF)
    Warranty 2 years
    Voltage 12 V
    Technology VRLA
    Battery Condition New
    Supported UPS Any UPS providing supported charging current
    Water Indication Level Since it is a Sealed Maintainance Free battery so no water indication level is required.
    Leak Proof Yes
    Led Indicator No
    Country of Origin Made in India
    Capacity (Ah) 26 Ah to 200 Ah
    Nominal Voltage 12 V
    330,000.00400,000.00

    Amaron Quanta Battery 12V/200AH

    330,000.00400,000.00
  • Sukam OnLine UPS 3kVA/180V 1-Phase to 1-Phase ‘Intelli’

    • Wide Input Voltage & Frequency Window
    • Built-in Galvanic Isolation Transformer
    • Auto-self Test on LCD Panel
    • Fuzzy Logic Controlled battery charging
    • Intelligent Battery Management
    • Scalable Runtime
    • Cold Start
  • Srne Lithium Ion Battery 48v 5.12KW

    • Model: ES-5.12KWH.
    • Warranty: 5 years.
    • Rated Capacity (5HR): 110Ah.
    • Voltage: 51.2V.
    • Discharge Cutoff Voltage: 40.0V.
    • Equalised Charge Voltage: 58.4V.
    • Maximum Charging Current: 100A.
    • Maximum Discharging Current: 100A.
    • C. Rating: 1.0C.
    • Display: LCD.
    • Parallel: Parallel connection up to 15 packs with full communications.
    • Dimensions (WxDxH): 505mm x 162mm x 543mm.
    • Ports: 1x CAN Bus, 1x RS-485 Battery Link ports, 2x Parallel Instruction Ports.
    • Cells: New Li-Ion Prismatic Cells.
    • Design Life: -/+ 15 Years.
    • Cycle Life @ 1C: +/-4000 Cycles @ 100% DOD, Above 6000 cycles @ 80% DOD.
    • Certification: CE, UN38.3, IEC, MSDS.
    • Outer Package Material: White bske lacquer steel case.
    • Operating Temperature: Charging: 0 to 50°C, Discharging: -10 to 50°C, Storage: -10 to 50°C.
    • Protection: Electronic Circuit Breaker, BMS Voltage Protection, Current Limiting.
  • MPPT Solar Charging Controller MA2460N15

    ◆Using MPPT technology, the tracking efficiency of MPPT can reach 99.9%.
    ◆Support CAN communication function (optional).
    ◆Supports a wide variety of batteries such as sealed, colloidal, open-type, lithium battery and user-customized battery.
    ◆Support line loss compensation of charging voltage, so that the battery charging voltage control is more accurate (partial models).
    ◆Support starting capacitive load and inductive load.
    ◆RS485 communication supporting standard Modbus protocol, with baud rate adjustable.
    ◆Support TTL communication of standard Modbus protocol, with baud rate fixed.
    ◆With perfect charging and discharging protection mechanism such as supervoltage, overcurrent, overload, overtemperature and short-circuiting.
    ◆ Using high-quality aluminum radiator and high-temperature derating processing can ensure reliable and efficient operation in each work environment.

  • SRNE 230Ah Genus Tubular

    • Patented Carbon-based technology tubular battery for inverters
    • Nano-materials that ensure that the battery plates are more resistant & durable
    • High purity lead & thicker plate for robust performance
    • Heavy-duty tubular battery delivering rugged Performance
    • Robust grid design
    • 230Ah/12V Tubular Battery with 25% longer life over Similar Products
    • Improved Charge Acceptance
    • Enhanced Backup Capacity
    • Fits with all type of Inverters
    • Deep Discharge Recovery & Charge Acceptance Characteristics
    • High Acid Volumes Help With Lower Maintenance
    • Fast Charging Capacity
    • Resistance to Corrosion Improves Battery Life
    • Clear Electrolyte Level Indicator
    • Designed for demanding usage conditions
    • Its technology allows for greater depth-of-discharge & delivers more charge cycles
    • 24 Months Warranty
  • Srne 20Tubular

    • A Battery made for everyone’s needs, be it with Solar or without Solar. No need to change battery if you convert to Solar
    • All-Purpose Fast Charging and Long Lasting Inverter/UPS Battery with 200Ah Capacity at C20 Rating and 60 Months Warranty (36 Months Full Replacement + 24 Months Pro Rata Warranty)
    • Genus provides Extremely Battery Preventive Maintenance Plans, so that you can get life of 6-7 years from this battery
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3

Main Menu