-
APC Back-UPS 700VA – BX700UI
Key Features
LED status displayQuickly understand unit and power status with visual indicators.
Audible alarmsProvides notification of changing utility power and UPS power conditions
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
Intelligent battery managementMaximizes battery performance, life, and reliability through intelligent, precision charging.
Battery failure notificationProvides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic self-testPeriodic battery self-test ensures early detection of a battery that needs to be replaced. -
APC 700VA UPS
Key Features- Output power capacity: 390 Watts / 700 VA
- Max Configurable Power (Watts): 390 Watts / 700 VA
- Nominal Output Voltage: 230V
- Output Frequency (sync to mains): 50/60 Hz +/-1 Hz
-
APC 650VA SMART UPS -BX650LI-MS
Key Features- Early warning fault analysis on batteries
- Easy recovery from overloads
- Provides temporary battery power when the utility power is out
- Automatically steps up low voltage
- Automatically steps down high voltage to levels that are suitable for your equipment
-
₦7,000,000.00
₦9,000,000.00100KVA Three Phase Servo Voltage Stabilizer 380V (±30%) input
₦7,000,000.00₦9,000,000.00 -
Prag 12v 150ah Tubular Gel Battery
*Sealed maintenance free – no topping up ever*Excellent deep discharge capability*High recharge efficiency*Superior cycle life*Less sensitive to temperature*Long shelf life*Greater design life – best value for money*Supplied factory charged -
-
4KVA – 24V Inverter – H
nverter Output Model PT-INV-4KVA 24V-Color LED, Wall-H Continuous Output Power 3000W Surge Rating(20s) 9000W Capable of Starting Electric Motor 3HP Output Waveform Pure Sine wave/Same as input(Bypass mode) Nominal Efficiency >88%(Peak) Line Mode Efficiency >95% Power Factor 0.9-1.0 Nominal Output Voltage rms 100-110-120Vac / 220-230-240Vac Output Voltage Regulation ±10% RMS Output Frequency 50/60Hz ± 0.3Hz Short Circuit Protection Yes, Current Limit Function (Fault after 1sec) Typical transfer Time 10ms(Max) THD < 10% DC Input Nominal Input Voltage 12.0Vdc ( *2 for 24Vdc, *4 for 48Vdc) Minimum Start Voltage 10.0Vdc Low Battery Alarm 10.5Vdc / 11.0Vdc Low Battery Trip 10.0Vdc / 10.5Vdc High Voltage Alarm & Fault 16.0Vdc High DC Input Recovery 15.5Vdc Low Battery voltage recover 13.0Vdc Idle Consumption-Search Mode < 25 W when Power Saver On Charge Input Voltage Range Wide: 90~135VAC / 164~243VAC
Narraw: 100~135VAC / 194~243VACInput Frequency Range Narrow: 47-55±0.3Hz for 50Hz, 57-65±0.3Hz for 60Hz
Wide:43±0.3Hz plus for 50Hz/60HzOutput Voltage Depends on battery type Charger Breaker Rating 30A Max Charge Rate 30 ± 5A Over Charge Protection Shutdown 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc) Charger curve(4 stage constant current)
4 step digital controlled progressive chargeBattery types ( *2 for 24Vdc, *4 for 48Vdc) Battery type Fast Vdc Gel U.S.A 14.0 A.G.M 1 14.1 A.G.M 2 14.6 Sealed Lead Acid 14.4 Gel Euro 14.4 Open Lead Acid 14.8 Calcium 15.1 De-sulphation 15.5 for 4hrs Remote Control Yes. Optional Bypass & Protection Input Voltage Waveform Sine wave (Grid or Generator) Nominal Voltage 120Vac Low Voltage Trip 80V/90V±4% Low Voltage re engage 90V/100V±4% High Voltage Trip 140V±4% High Voltage re engage 135V±4% Max Input AC Voltage 150VAC Nominal Input Frequency 50Hz or 60Hz (Auto detect) Low Freq Trip Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
Wide:40±0.3Hz for 50Hz/60HzLow Freq re engage Narrow: 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz
Wide:42±0.3Hz for 50Hz/60HzHigh Freq Trip Narrow: 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
Wide: 70±0.3Hz for 50Hz/60HzHigh Freq re engage Narrow: 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz
Wide: 68±0.3Hz for 50Hz/60HzOutput Short circuit protection Circuit breaker Bypass breaker rating 30A Transfer switch rating 40amp for UL Max bypass current 40amp Mechanical Specification Mounting Wall mount Inverter Dimensions(L*W*H) 670*350*300mm Inverter Weight 17KG Shipping Dimensions(L*W*H) 585x320x310mm Shipping Weight 20KG Display Status LEDs / Status LEDs+LCD Standard Warranty 1 Year ₦723,000.00₦900,000.004KVA – 24V Inverter – H
₦723,000.00₦900,000.00