• 4KVA – 24V Inverter – H

    nverter Output
    Model PT-INV-4KVA 24V-Color LED, Wall-H
    Continuous Output Power 3000W
    Surge Rating(20s) 9000W
    Capable of Starting Electric Motor 3HP
    Output Waveform Pure Sine wave/Same as input(Bypass mode)
    Nominal Efficiency >88%(Peak)
    Line Mode Efficiency >95%
    Power Factor 0.9-1.0
    Nominal Output Voltage rms 100-110-120Vac / 220-230-240Vac
    Output Voltage Regulation ±10% RMS
    Output Frequency 50/60Hz ± 0.3Hz
    Short Circuit Protection Yes, Current Limit Function (Fault after 1sec)
    Typical transfer Time 10ms(Max)
    THD < 10%
    DC Input
    Nominal Input Voltage 12.0Vdc
    ( *2 for 24Vdc, *4 for 48Vdc)
    Minimum Start Voltage 10.0Vdc
    Low Battery Alarm 10.5Vdc / 11.0Vdc
    Low Battery Trip 10.0Vdc / 10.5Vdc
    High Voltage Alarm & Fault 16.0Vdc
    High DC Input Recovery 15.5Vdc
    Low Battery voltage recover 13.0Vdc
    Idle Consumption-Search Mode < 25 W when Power Saver On
    Charge
    Input Voltage Range Wide: 90~135VAC / 164~243VAC
    Narraw: 100~135VAC / 194~243VAC
    Input Frequency Range Narrow: 47-55±0.3Hz for 50Hz, 57-65±0.3Hz for 60Hz
    Wide:43±0.3Hz plus for 50Hz/60Hz
    Output Voltage Depends on battery type
    Charger Breaker Rating 30A
    Max Charge Rate 30 ± 5A
    Over Charge Protection Shutdown 15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc)
    Charger curve(4 stage constant current)
    4 step digital controlled progressive charge
    Battery types ( *2 for 24Vdc, *4 for 48Vdc)
    Battery type Fast Vdc
    Gel U.S.A 14.0
    A.G.M 1 14.1
    A.G.M 2 14.6
    Sealed Lead Acid 14.4
    Gel Euro 14.4
    Open Lead Acid 14.8
    Calcium 15.1
    De-sulphation 15.5 for 4hrs
    Remote Control Yes. Optional
    Bypass & Protection
    Input Voltage Waveform Sine wave (Grid or Generator)
    Nominal Voltage 120Vac
    Low Voltage Trip 80V/90V±4%
    Low Voltage re engage 90V/100V±4%
    High Voltage Trip 140V±4%
    High Voltage re engage 135V±4%
    Max Input AC Voltage 150VAC
    Nominal Input Frequency 50Hz or 60Hz (Auto detect)
    Low Freq Trip Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
    Wide:40±0.3Hz for 50Hz/60Hz
    Low Freq re engage Narrow: 48±0.3Hz for 50Hz, 58±0.3Hz for 60Hz
    Wide:42±0.3Hz for 50Hz/60Hz
    High Freq Trip Narrow: 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz
    Wide: 70±0.3Hz for 50Hz/60Hz
    High Freq re engage Narrow: 54±0.3Hz for 50Hz, 64±0.3Hz for 60Hz
    Wide: 68±0.3Hz for 50Hz/60Hz
    Output Short circuit protection Circuit breaker
    Bypass breaker rating 30A
    Transfer switch rating 40amp for UL
    Max bypass current 40amp
    Mechanical Specification
    Mounting Wall mount
    Inverter Dimensions(L*W*H) 670*350*300mm
    Inverter Weight 17KG
    Shipping Dimensions(L*W*H) 585x320x310mm
    Shipping Weight 20KG
    Display Status LEDs / Status LEDs+LCD
    Standard Warranty 1 Year

     

    723,000.00900,000.00

    4KVA – 24V Inverter – H

    723,000.00900,000.00
  • 20KVA (95V-280V)RELAY VOLTAGE STABILIZER

    Description

    • Overview

      Low, High, Fluctuating NEPA Voltage?

      One Central Stabilizer for your entire Flat, Home, Office, etc.

      Input Voltage Range of 95V-280V

      Stablize and Protect all electrical appliances in your premises: Air Conditioners, Fridges, Freezers, TV, Home Theatre, DVD, Satellite Decoder, Electronics, Lights, Fans, Washing Machine, Microwave, Pumping Machine, Photocopier, Printer, Desktops, Notebooks, etc.

      TMH95-20K Relay Automatic Voltage Stabilizer Series is based on digital technology; provides voltage stabilization and protection to appliances and equipment; designed as a central stabilizer to handle all house loads.

  • 20KVA (45V-280V)RELAY VOLTAGE STABILIZER

    Description

    Overview

    Low, High, Fluctuating NEPA Voltage?

    One Central Stabilizer for your entire Flat, Home, Office, etc.

    Extreme Wide Input Voltage (45-280V)

    Stablize and Protect all electrical appliances in your premises: Air Conditioners, Fridges, Freezers, TV, Home Theatre, DVD, Satellite Decoder, Electronics, Lights, Fans, Washing Machine, Microwave, Pumping Machine, Photocopier, Printer, Desktops, Notebooks, etc.

    TMH45-20K Relay Automatic Voltage Stabilizer Series is based on digital technology; provides voltage stabilization and protection to appliances and equipment; designed as a central stabilizer to handle all house loads.

    600,000.00700,000.00

    20KVA (45V-280V)RELAY VOLTAGE STABILIZER

    600,000.00700,000.00
  • Prag 10KVA Servo Voltage Stabilizer (140V-260V)

    01

    Overview

    The Prag 10KVA Servo Central Stabilizer Stablize, Protect all electrical.

    Low, High, Fluctuating NEPA Voltage?

    One Central Stabilizer for your entire House, Flat or Office*.

    Stablize and Protect all electrical appliances in your premises: Air Conditioners, Fridges, Freezers, TV, Home Theatre, DVD, Satellite Decoder, Electronics, Lights, Fans, Washing Machine, Microwave, Pumping Machine, Photocopier, Printer, Desktops, Notebooks, etc.

    PC-SVS or Programmed Control Servo Voltage Stabilizer Series is based on digital technology. Due to special transformer servo technology, PC-SVS can handle inductive load such as air conditioners and take greater surge which offers more reliability and performance than traditional relay stabilizers. PC-SVS provides voltage stabilization and protection to appliances and equipment. PC-SVS is designed as a central stabilizer to handle all house loads.

    Features

    • Wide input voltage
    • Steady output voltage
    • Digital Control
    • Servo Technology
    • Wall mounted
    • Low and Over voltage protection

    Applications

    • Home Appliances
    • Office Equipment
    • Medical Equipment
    • Sensitive Equipment
    • General Use
    400,000.00500,000.00
  • TMA-10KVA (95-270V)-RELAY-PB

    PRAG TMA-10KVA (95-270V)-RELAY-PB Stablize’s and protect all electrical appliances in your premises, both home and office. This includes Air Conditioners, Fridges, Freezers, TV, Home Theatre, DVD, Satellite Decoder, Electronics, Lights, Fans, Washing Machine, Microwave, Pumping Machine, Photocopier, Printer, Desktops, Notebooks, etc.

    Low, High, Fluctuating NEPA Voltage?

    Firstly, if you are having low or high NEPA voltage current in your house or office, you can go for our 5kva stabilizer with good quality and fantastic price in Nigeria. One Central Stabilizer from PRAG for your entire Flat, Home, Office, etc will do the job.

    Equally important to note is that the Input Voltage for our PRAG TMA-10KVA (95-270V)-RELAY-PB.

    Moreover, our stabilizers are of the best quality and good prices. They also Stablize and Protect all electrical appliances in your premises: Air Conditioners, Fridges, Freezers, TV, Home Theatre, DVD, Satellite Decoder, Electronics, Lights, Fans, Washing Machine, Microwave, Pumping Machine, Photocopier, Printer, Desktops, Notebooks, etc.

    In addition to all these, the 10KVA (95-270V)-RELAY is based on digital technology that provides voltage stabilization and protection to appliances and equipment.  As a matter of fact, they are designed as a central stabilizer to handle all house or office loads. Finally, this means that your entire load should not be more than the capacity of your Stabilizer at any given point.

    215,000.00290,000.00

    TMA-10KVA (95-270V)-RELAY-PB

    215,000.00290,000.00
  • PRAG 7.5KVA/48V Inverter 8 X 12V 220AH Battery 16 X 250W Solar Panel Roof-Top off-grid Complete Installation

    • The PRAG Inverter is Easy to Install and Easy to Operate. This inverter is also Easy to Solve
    • It is also designed to Operate under Harsh Environment
    • The Inverter comes with the ability to do a DC Start & Automatic Self-Diagnostic Function
    • It is Compatible with Both Linear & Non-Linear Load
    • Low DC Voltage Supports Home & Office Appliances on the inverter
    • With this PRAG Inverter, you can enjoy Powerful Charge Rate Up to 120Amp, Selectable From 0%-100%
    • High Efficiency Inverter Design & “Power Saving Mode” to Conserve Energy
    • Battery Priority Mode, Designates the Inverter-Preferred UPS Configuration
    • 13 Vdc Inverter Battery Recover Point, Dedicated for Renewable Energy Systems
    • 8 pre Set Battery Type Selector plus De-sulphation for Totally Flat Inverter Batteries
    • 4-step Intelligent Battery Charging, PFC (Power Factor Correction) for Charger
    • 8 ms Typical Transfer Time Between Utility & Inverter Battery, Guarantees Power Continuity
    • 15s Delay Before Transfer when AC Resumes, Protection for Load when Used with Generator
    • Battery DOD(Depth of Discharge)setting from 50% to 100%

Main Menu