EG 650-3000VA
Input Voltage: 220 / 230 / 240 Vac Tolerance Normal Over-voltage: 280V Withstand Over-voltage: 284V (max limit 285V) Under-voltage limit: 145V (lowest limit 142V) Output Voltage: 220/230V ± 10%, ± 1% on battery Power Factor 0.6 . Transfer Time: 2 – 6 ms (Typical) Frequency: 50Hz (On Battery) Waveform: Sine Wave on normal; Simulated Sine on battery DC Bus: 650VA 12V 1000VA 24V 1500VA 24V 2000VA 24V 3000VA 48V Cold-Start Function: Yes Charging Time: 6hr to recover to 90% capacity Battery Charging in OFF Mode: Yes User Interface: Indications for Normal mode Battery mode / mains fail Low battery UPS fault Environment: Temperature: 0 ~ 40oC Humidity: 20 ~ 90% Non-condensing Noise Level: Noise Level: Less than 40dB Physical: Dimensions 600 – 650VA: 279x101x142 (DxWxH) 1000 – 2000VA: 320x130x182 (DxWxH) 3000VA: 460x138x166 (DxWxH) Weight (Kg) 650VA : 4.3 1000VA : 7.9 1500VA : 11 2000VA : 10.7 3000VA : 19.7 -
DG 600-3000VA
Input Voltage: 220 / 230 / 240 Vac Tolerance Normal Over-voltage: 280V Withstand Over-voltage: 284V (max limit 285V) Under-voltage limit: 145V (lowest limit 142V) Output Voltage: 220/230V ± 10%, ± 1% on battery Power Factor 0.6 . Transfer Time: 2 – 6 ms (Typical) Frequency: 50Hz (On Battery) Waveform: Sine Wave on normal; Simulated Sine on battery DC Bus: 650VA 12V 1000VA 24V 1500VA 24V 2000VA 24V 3000VA 48V Cold-Start Function: Yes Charging Time: 6hr to recover to 90% capacity Battery Charging in OFF Mode: Yes User Interface: Indications for Normal mode Battery mode / mains fail Low battery UPS fault Environment: Temperature: 0 ~ 40oC Humidity: 20 ~ 90% Non-condensing Noise Level: Noise Level: Less than 40dB Physical: Dimensions 600 – 650VA: 279x101x142 (DxWxH) 1000 – 2000VA: 320x130x182 (DxWxH) 3000VA: 460x138x166 (DxWxH) Weight (Kg) 650VA : 4.3 1000VA : 7.9 1500VA : 10 2000VA : 10.7 3000VA : 19.7 -
SMKSolar 60A MPPT Fancooling Solar charger controller
Model SCF-50A SCF-60A Solar System Voltage 12V/24V/48V Auto work Electrical PV Operating Voltage 18~150Vdc@12V 35~150Vdc@24V 60~150Vdc@48V Max. PV input power 12V 700W 12V 900W 24V 1400W 24V 1800W 48V 2900W 48V 3400W Rated input current 50A 60A Self consumption 3W Max.Conversion Efficiency 97.6% Protection PV array short circuit, over charging,battery reverse polarity,output short circuit Battery charging Battery Type Sealed Gel AGM Flooded Charge algorithm 3 stage: Bulk, Absorption, Float Bulk charge voltage Sealed: 14.4V AGM 14.2V Gel:14.2V Flooded:14.6V User defined:10-15V Float charge voltage Sealed/Gel/AGM:13.8V Flooded:13.7V User defined:10-15V Equalize charge voltage Sealed 14.6V AGM:14.8V Flooded:14.9V Low voltage reconnect voltage 12.5V Temperature compensation 5mV/℃/2V with BTS Communication Communication Port RS485(Standard) Ethernet RS232 Optional with On line monitoring system Physical Net weight 3kg Gross weight 4kg Dimension 280*180*89MM Cooling Fan cooling Enclosure IP20 Environment Ambient operating temperature -25℃~60℃ Storage Temperature -40℃~80℃ Humidity 100% non-condensing Warranty One years -
96V 60A-2 input SOLAR CHARGE CONTROLLER
Technical data
60A-2 inputs)
Model CP-9660 Rated power(W) 7.2K Rated charge current(A) 60A Rated battery voltage(VDC) 96 Solar input Max. PV voltage(VDC) ≤175 Charge voltage range(VDC) 80-175 2 inputs SOLAR1 SOLAR2 Max. power for each input(Wp) 2.88K 2.88K Max. input current for each input(A) 30 30 Overcharge protect voltage(VDC) 111.95 Overcharge recovery voltage(VDC) 109.6 DC output Rated output current(A) 50 Low voltage protect voltage(VDC) 87.7 High voltage protect voltage(VDC) 124 Efficiency >98% Protection Charge over-current, over-voltage/DC output low voltage/high voltage/over-current .,etc
Fan starting temperature >45℃ Operating temperature 0-40℃ Storage temperature -15 – +50℃ Operating/storage environment 0-90%no condensation Product size:W*D*H(mm) 389*320*98 Package size:W*D*H(mm) 430*395*180 -
120V 60A-2 INPUTS SOLAR CHARGE CONTROLLER
Technical data
60A-2 inputs
Model CP-120060 Rated power(W) 7.2K Rated charge current(A) 60A Rated battery voltage(VDC) 120 Solar input Max. PV voltage(VDC) ≤219 Charge voltage rage(VDC) 100-219 2 inputs SOLAR1 SOLAR2 Max. power for each input(Wp) 3.6K 3.6K Max. input current for each input(A) 30 30 Overcharge protect voltage(VDC) 139.9 Overcharge recovery voltage(VDC) 137 DC output Rated output current(A) 50 Low voltage protect voltage(VDC) 109.6 High voltage protect voltage(VDC) 155 Efficiency >98% Protection Charge over-current, over-voltage/DC output low voltage/high voltage/over-current .,etc
Fan starting temperature >45℃ Operating temperature 0-40℃ Storage temperature -15 – +50℃ Operating/storage environment 0-90%no condensation Product size:W*D*H(mm) 389*320*98 Package size:W*D*H(mm) 430*395*180 -
1.5KVA Hybrid Inverter + 1 X 12V 200AH Battery grid-tie Complete Installation
Solar Batteries 12V/200AH x 1pcs Inverter 1.5kva X 1 pcs Mounting Structure For 1KW System DC Junction Box 1 pcs Wires & Cables Standard Pack Protection Devices As Required Lighting Protection 1 pcs