• RiiO 2KVA/48V -M Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3
  • TBB RiiO 3KVA-24V Inverter Charger

    3KVA-24V Solar Hybrid Pure Copper Low Frequency Transformer based
    Optional remote monitoring Eco mode/Power assist

     

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built-in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • TBB RiiO 3KVA-M 24V Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal
  • TBB RiiO 3KVA-M 48V Inverter Charger

    Generator power assist function enables small generators to handle big loads
    Load boost function for running the heavy duty loads
    Save 45% energy at max under the built in ECO Mode (30% on average)
    Extremely high inverter efficiency up to 94%
    Harmonic distortion <2%
    Extremely low self-consumption power
    High performance designed for all kinds of inductive loads
    TBB premium II battery charging management
    Built in SOC estimation
    Equalization charging program available for flooded and OPZS battery
    Lithium battery charging available
    Fully programmable by APP
    Remote monitoring and control via Nova online portal

Main Menu