• Amaron Quanta Battery 12V/200AH

    Product Details:

    Brand Amaron Quanta
    Capacity 26Ah to 200Ah
    Battery Type Sealed Maintenance Free (SMF)
    Warranty 2 years
    Voltage 12 V
    Technology VRLA
    Battery Condition New
    Supported UPS Any UPS providing supported charging current
    Water Indication Level Since it is a Sealed Maintainance Free battery so no water indication level is required.
    Leak Proof Yes
    Led Indicator No
    Country of Origin Made in India
    Capacity (Ah) 26 Ah to 200 Ah
    Nominal Voltage 12 V
    330,000.00400,000.00

    Amaron Quanta Battery 12V/200AH

    330,000.00400,000.00
  • SERNE 4 by 4 Breaker cover

    Models HT4830S80-145 HT4840S80-145 HT4850S80-145
    AC mode
    Rated input voltage 220/230Vac
    Input voltage range (170Vac~280Vac) ±2%/(90Vac-280Vac)±2%
    Frequency 50Hz/ 60Hz (automatic detection)
    Frequency range 47±0.3Hz ~ 55±0.3Hz (50Hz);57±0.3Hz ~ 65±0.3Hz (60Hz);
    Overload/short circuit protection Circuit breaker
    Efficiency >95%
    Conversion time (bypass andinverter) 10ms (typical)
    AC backflow protection yes
    Maximum bypass overload current 40A
    Inverting mode
    Output voltage waveform Pure sine wave
    Rated output power (VA) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Rated output power (W) 3000(2600/2700/3000) 4000(3480/3600/3800/4000) 5000(4350/4500/4800/5000)
    Power factor 1
    Rated output voltage (Vac) 230Vac(200/208/220/240Vac Settable)
    Output voltage error ±5%
    Output frequency range (Hz) 50Hz ± 0.3Hz/60Hz ± 0.3Hz
    Efficiency >92%
    Overload protection (102%<load<125%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 5=”” minutes;<=”” p=””></load<125%)>

    (125%<load<150%) ±10%:=”” report=”” error=”” and=”” turn=”” off=”” output=”” after=”” 10=”” seconds;<=”” p=””></load<150%)>

    Load>150% ±10%: Report error and turn off output after 5 seconds;

    Peak power 6000VA 8000VA 10000VA
    Loaded motor capacity 2HP 3HP 4HP
    Output short circuit protection Circuit breaker
    Bypass circuit breaker specification 63A
    Rated battery input voltage 48V (minimum starting voltage 44V)
    Battery voltage range 40.0Vdc~60Vdc ± 0.6Vdc (undervoltage alarm / shutdown voltage / overvoltage alarm / overvoltage recovery…LCD screen can be set)
    Eco mode Load ≤50W
    AC charge
    Battery type Lead acid or lithium battery
    Maximum charge current 60A
    Charge current error ± 5Adc
    Charge voltage range 40 –58Vdc
    Short circuit protection Circuit breaker
    Circuit breaker specification (AC IN)63A/(BAT)125A
    Overcharge protection Alarm and turn off charging in 1 minute.
    Solar charge
    Maximum PV open circuit voltage 145Vdc
    PV operating voltage range 60-145Vdc
    MPPT voltage range 60-115Vdc
    Battery voltage range 40-60Vdc
    Maximum output power 4200W
    PV charge current range (settable) 0-80A
    Charge short circuit protection BAT circuit breaker and fuse
    Wiring protection Reverse polarity protection
    Authentication specification
    Specification certification CE(EN62109)
    EMC certification level EN61000,C2
    Operating temperature range -15°C to 55°C
    Storage temperature range -25°C ~ 60°C
    RH range 5% to 95% (conformal coating protection)
    Noise ≤60dB
    Heat dissipation Forced air cooling, adjustable air speed
    Communication interface USB/RS485 (WiFi/GPRS)/Dry Node Control
    Dimensions (L*W*D) 482mm*425mm*133mm
    Weight (kg) 13.3