Total Power Range

Gross Mechanical Output 412-623 kWm
Typical Electrical Output 455-687 kVA (364-550 kWe)
Rated Speed 1500/1800 rpm

50 Hz Typical Electrical Output

Prime 455-500 kVA
Standby 500-550 kVA

60 Hz Typical Electrical Output

Prime 400-468 kWe
Standby 450-550 kWe

Emission Standards

Emissions EU 97/68/EC Stage II, EPA Tier 2

General

Number of Cylinders 6 vertical inline
Bore 137 mm
Stroke 171 mm
Displacement 15.2 l
Compression Ratio 16.0:1
Aspiration Turbocharged and air-to-air chargecooled
Combustion System Direct injection
Rotation from Flywheel End Anti-clockwise
Cooling System Liquid
Aftertreatment
Typical Alternator Efficiency 92%
Switchable Yes

ElectropaK Dimensions

Length 2657 mm
Width 1120 mm
Height 1718 mm
Dry Weight 1633 kg

Disclaimer

Note 1 *Final dimensions dependent on selected options

Definitions

Prime Power Variable load. Unlimited hours usage with an average load factor of 80% of the published Prime Power rating over each 24 hour period. A 10% overload is available for 1 hour in every 12 hours operation.
Standby Power Variable load. Limited to 500 hours annual usage up to 300 hours of which may be continuous running. No overload is permitted.

The Perkins 2500 range of diesel engines provides you with output ratings of 455-624 kVA, catering for both your prime and standby power generation needs. The features and benefits of the 2000 Series ensure your generator needs are met. Flexible packaging of the 6 cylinder engines caters for the space you have available, and with mechanically operated unit fuel injectors, electronic control, and carefully matched turbocharging, our 2500 range gives you performance and economy.

Variants certified against the requirements of EU Stage II/U.S. EPA Tier 2 emissions standards for non-road mobile machinery, powered by constant speed engines.