PERKINS 1104D-E44TG

Availability:

Out of stock


Total Power Range

Gross Mechanical Output 65-72 kWm
Typical Electrical Output 68-75 kVA (54-60 kWe)
Rated Speed 1800 rpm

60 Hz Typical Electrical Output

Prime 54.5 kWe
Standby 60 kWe

Emission Standards

Emissions EU Stage IIIA/U.S. EPA Tier 3

General

Number of Cylinders 4 inline
Bore 105 mm
Stroke 127 mm
Displacement 4.4 l
Compression Ratio 16.7:1
Aspiration Turbocharged
Combustion System Direct injection
Rotation from Flywheel End Anti-clockwise
Cooling System Liquid
Aftertreatment
Typical Alternator Efficiency 88.5%
Switchable No

ElectropaK Dimensions

Length 1280 mm
Width 717 mm
Height 967 mm
Dry Weight 439 kg

Disclaimer

Note 1 *Final dimensions dependent on selected options
Note 2 ESE (1800 rpm) only – Emergency Stationary Equipment

Definitions

Prime Power Power available at variable load in lieu of a main power network. Overload of 10% is permitted for one hour in every 12 hours of operation.
Standby Power Power available at variable load in the event of a main power network failure. No overload is permitted.

Our 1104 ElectropaK engines set the industry standard for prime and standby power generation. The 4 cylinder, 4.4 litre engines are smooth and quiet in operation. They can also be electronically controlled, giving you the right fuel combustion for the load applied to the engine. The engines deliver 43.7-126.5 kVA, meeting the key power nodes.