-7%

KARTEL 15KVA 120V 3Phase NB-153120 HDSX SERIES INVERTER (3 PHASE)


    • Specification
      Model HDSX 10KVA 15KVA 20KVA 25KVA
      Rated Power 8KW 12KW 16KW 20KW
      Peak Power(20ms) 24KW 36KW 48KW 60KW
      Starter Motor 5HP 7HP 10HP 10HP
      Battery Voltage 48/96/192VDC 96/192/384VDC
      Size(L*W*Hmm) 565*300*775
      Packing Size(L*W*Hmm) 625*360*895
      N.W.(kg) 122 134 160 176
      G.W.(kg)(Carton Packing) 146 158 184 200
      Installation Method Tower
      Parameter
      Input DC Input Voltage Range 10.5VDC-15VDC(Single battery voltage)
      AC Input Voltage Range 380Vac/400Vac±10%(customized 190Vac/200Vac)
      AC Input Frequency Range 45Hz-65Hz
      Max AC charging current 25A/15A/10A 30A/20A/10A 30A/20A/10A 45A/30A/15A
      AC charging method Three-stage (constant current, constant voltage, floating charge)
      Phase 3/N/PE
      Output Efficiency(Battery Mode) ≥85%
      Output Voltage(Battery Mode) 380Vac/400Vac±10%(customized 190Vac/200Vac)
      Output Frequency(Battery Mode) 50/60Hz ±1%
      Output Wave(Battery Mode) Pure Sine Wave
      Output waveform distortion Linear load≤3%
      Efficiency(AC Mode) >99%
      Output Voltage(AC Mode) Conforming to AC input
      Output Frequency(AC Mode) Conforming to AC input
      No load loss(Battery Mode) ≤1%  rated power
      No load loss(AC Mode) ≤2%  rated power( charger does not work in AC mode)
      No load loss(Energy saving Mode) ≤10W
      Phase 3/N/PE
      Battery type
      (Optional)
      U0: Gel U.S.A Charge Voltage:14V;Float Voltage:13.7V(Single battery voltage)
      U1: A.G.M.1 Charge Voltage:14.1V;Float Voltage:13.4V(Single battery voltage)
      U2:  A.G.M.2 Charge Voltage:14.6V;Float Voltage:13.7V(Single battery voltage)
      U3: Sealed lead Acid Charge Voltage:14.4V;Float Voltage:13.6V(Single battery voltage)
      U4: Gel European Charge Voltage:14.4V;Float Voltage:13.8V(Single battery voltage)
      U5: Open lead Acid Charge Voltage:14.8V;Float Voltage:13.5V(Single battery voltage)
      U6: Calcuim(open) Charge Voltage:15.1V;Float Voltage:13.6V(Single battery voltage)
      U7: Sulphation cycle 15.5V for 4hrs
      customize battery Charge and discharge parameters of different types of batteries (such as lithium batteries, etc.)
      can be customized according to user requirements.
      Protection Battery undervoltage alarm 11V(Single battery voltage)
      Battery undervoltage protection 10.5V(Single battery voltage)
      Battery overvoltage alarm 15V(Single battery voltage)
      Battery overvoltage protection 17V(Single battery voltage)
      Battery overvoltage recovery voltage 14.5V(Single battery voltage)
      Overload power protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
      Output short circuit protection Automatic protection (battery mode), circuit breaker or insurance (AC mode)
      Temperature protection >90°C(Shut down output)
      Alarm A Normal working condition, buzzer has no alarm sound
      B Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection
      C When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal
      Inside Solar controller
      (Optional)
      Charging Mode MPPT or PWM
      Charging current 10A/20A/30A/40A/50A/60A(48V system); PWM: 50A/100A/150A/200A(96V/192V/384V system);  MPPT: 50A/100A(96V/192V/384V system)
      PV Input Voltage Range PWM: 60V-88V(48V system); 120V-176V(96V system); 240V-352V(192V system); 480V-704V(384V system)
      MPPT:  60V-120V(48V system); 120V-240V(96V system); 240V-360V(192V system);  480V-640V(384V system)
      Max PV Input Voltage(At 25℃) PWM:  100V(48V system); 200V(96V system); 400V(192V system); 750V(384V system)
      MPPT: 150V(48 system); 300V(96V system); 450V(192V system); 750V(384V system)
      PV Array Maximum Power 48V system: 560W/1120W/1680W/2240W/2800W/3360W; 96V system: (PWM: 5.6KW/11.2KW) / (MPPT: 5.6KW/5.6KW*2);
      192V system: (PWM: 11.2KW/22.4KW/16.8KW*2/22.4KW*2) / (MPPT: 11.2KW/11.2KW*2);
      384V system: (PWM: 22.4KW/44.8KW/33.6KW*2/44.8KW*2) / (MPPT: 22.4KW/22.4KW*2)
      Standby loss ≤3W
      Maximum conversion efficiency >95%
      Working Mode Battery First/AC First/Saving Energy Mode
      Transfer Time ≤4ms
      Display LCD
      Thermal method Cooling fan in intelligent control
      Communication RS232/RS485/APP/SNMP/GSM (Optional)
      Environment Operating temperature -10℃~40℃
      Storage temperature -15℃~60℃
      Noise 2000m(More than derating)
      Elevation ≤65dB
      Humidity 0%~95% ,No condensation
      Warranty 1 year
      Note: All specifications are subject to change without prior notice

 

1,410,525.00 1,510,000.00

3Phase HDSX SERIES INVERTER 20KVA/96v/120v/192v NB-20396/NB-203120

HDSX 3 Phase Inverter Hybrid 10KVA 15KVA 20KVA 25KVA

  • Rated Power : 10KVA 15KVA 20KVA 25KVA

  • DC Input Voltage: 10.5-15VDC(Single battery voltage)

  • AC Input Voltage : 85VAC~138VAC / 170VAC~275VAC

  • Output Voltage : 110VAC±2% / 220VAC±2%

  • Output Frequency: 50/60Hz±1%

  • Output Wave: Pure sine wave

How does Three Phase Hybrid Inverter work?

1. Home backup system: When AC grid power is available, inverter charges the battery, at the same time, AC grid power bypass through an inverter to household appliances, such as refrigerator, TV. When AC grid power is off, it will automatically transfer the switch to battery power and convert DC to AC power.

2. Wind or Solar Power system: Convert DC to AC power. When battery power is lacking, it will automatically transfer to grid power for powering continuously.

3phase-hybrid-inverter-10k

 

 

 

  • 3 Phase Hybrid Inverter‘s Details

    3phase-hybrid-inverter-10k

10kva-25kva

 

 

    • Three Phase Hybrid Inverter Feature
    • ◆  Pure sine wave output.
    • ◇  Low DC voltage, saving system cost.
    • ◆  Built-in PWM or MPPT charge controller.
    • ◇  AC charge current 0-45A adjustable.
    • ◆  Wide LCD screen, clearly and precisely shows icon data.
    • ◇  100% imbalance loading design, 3 times peak power.
    • ◆  Setting different working modes based on variable usage requirements.
    • ◇  DC first/AC first optional.
    • ◆  Various communication ports and remote controls (RS232/RS485/APP/SNMP/GSM optional).

 

Category: Tags: ,

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “KARTEL 15KVA 120V 3Phase NB-153120 HDSX SERIES INVERTER (3 PHASE)”

There are no reviews yet.

× How can I help you?