-5%
,

10KVA/48V Hybrid inverter with inbuilt 200ah MMPT charge controller

Availability:

Out of stock


LCD display , easy to read how inverter operates on LCD screen
Compatible to generator
5-levels DIP switch , offering customized performance
9-levels battery selector , Enable to charge Li-thium , Gel , lead-acid battery
DC(Solar)/AC prority optional
4 levels charge current adjustable
With RS232 communication port
With BTS & GTS , optimazing battery performance & start generator automatically
Power saver Switch , Enable to minimize standby consumption.

1,060,000.00 1,120,000.00

Out of stock

10KVA/48V HYBRID INVERTER
INVERTER OUTPUT Rated power
Surge rating
Capable of starting electric motor
Waveform Pure sine wave \ same as input (bypass mode)
Nominal output voltage RMS 220V \ 230V \ 240VAC (±10%RMS)
Output frequency 50Hz \ 60Hz ± 0.3Hz
Inverter effciency(peak) >88%
Line mode efficiency >95%
Power factor 1.0
Typical transfer time 20ms(max)
AC INPUT Voltage 230VAC
Selectable voltage range 90-280 VAC (APL)
Frequency range 50Hz \ 60Hz
BATTERY Low battery voltage cutoff 20-24VDC for 24VDC mode (40-48VDC for 48VDC mode)
Low battery voltage recover 21-25VDC for 24VDC mode (42-50VDC for 48VDC mode)
High battery voltage cutoff 30VDC for 24VDC mode (60VDC for 48VDC mode)
High battery voltage recover 28.5VDC for 24VDC mode (57VDC for 48VDC mode)
Idle consumption-search mode <80W when power saver on
AC CHARGER Output voltage Depends on battery type
Charger AC input breaker rating 80A
Overcharge protection S.D. 31.4VDC for 24VDC mode (62.8VDC for 48VDC mode )
Maximum charge current 120A
BTS Continuous output power Yes Variances in charging voltage & S.D. voltage base on the battery temperature
BYPASS
& PROTECTION
Input voltage waveform Sine wave (grid or generator)
Nominal input frequency 50Hz or 60Hz
Overload protection (SMPS Load) Circuit breaker
Output short circuit protection Circuit breaker
Bypass breaker rating 63A
Max bypass current 80Amp
SOLAR CHARGER Maximum PV charge current 100A(200A optional)
DC voltage 48V
Maximim PV array power 5000W(10000W for 200A optional)
MPPT range @ operating voltage(VDC) 64~145VDC
Maximum PV array open circuit voltage 145VDC
Maximum effciency >98%
Standby power consumption <2W
MECHANICAL SPECIFICATIONS Mounting Wall mount
Dimensions (W*H*D) 670*410*215mm
Net weight (solar CHG) (kg) 75.75+2.5
Shipping dimensions (W*H*D) 884*618*443mm
Shipping weight (Solar CHG) (kg) 89+2.5
OTHER Operation temperature range 0°C to 40°C
Storage temperature -15°C to 60°C
Audible noise 60dB MAX
Display LED+LCD
Loading (20GP/40GP/40HQ) 140pcs \ 280pcs \ 320pcs